1-1/4''Corrugated Cable with Black PE Jacket
|
1-1/4'' Corrugated Cable with Black PE Jacket
|
 |
|
.jpg)
|
Construction Spectification |
|
|
Item
|
Material |
Diamenter (mm) |
|
1. Inner Conductor |
Smooth Copper Tube |
13.1 |
|
2. Dielectric |
Physical Foam Polyethylene |
33.3 |
|
3. Outer Conductor |
Corrugated Copper Tube |
36.0 |
|
4. Jacket |
Black PE |
38.6 |
|
|
|
|
|
Electrical Characteristics |
|
Capacitance (pF/M) |
|
76 |
|
Impedance (Ohm) |
|
50 |
|
Velocity of Propagation (%) |
|
88 |
|
Peak Power Rating (KW) |
|
205 |
|
RF Peak Voltage (KV) |
|
4.3 |
|
Insulation Resistance (MΩ.km) |
|
>5000 |
|
Cut-off Frequency (GHz) |
|
3.7 |
|
Insulation Voltage (KV) |
|
10 |
|
Inner Conductor DC Resistance (Ω/km) |
|
0.50 |
|
Outer Conductor DC Resistance (Ω/km) |
|
0.45 |
|
Jacket Spark (KV) |
|
10.0 |
|
Shielding Effectiveness (dB) |
|
>120 |
|
VSWR≤(Return loss≥dB) |
|
|
|
0.005-3GHz |
|
1.15 (23) |
|
0.8-1.0GHz |
|
1.10 (26) |
|
1.7-2.0GHz |
|
1.10 (26) |
|
2.0-2.4GHz |
|
1.10 (26) |
|
|
|
|
|
Mechanical and Environmental Characteristics |
|
Min. Single Bending Radius (mm) |
|
150 |
|
Min. Repeated Bending Radius (mm) |
|
380 |
|
No. of Bends |
|
15 |
|
Mobile Apply (mm) |
|
700 |
|
Bending Moment (N.m) |
|
43 |
|
Tensile Strength (kg) |
|
290 |
|
Storage Temp (℃) |
|
-55 to +85 |
|
Installation Temp (℃) |
|
-40 to +60 |
|
Operating Temp (℃) |
|
-55 to +85 |
|
|
|
|
|
Attenuation (VSWR1.0, cable temp. 20℃) & Average Power (VSWR 1.0, ambient temp. 40℃) |
|
Frequency (MHz) |
Attenuation (≯dB/100m) |
Average Power (KW) |
|
100 |
0.82 |
12.52 |
|
200 |
1.19 |
8.64 |
|
450 |
1.85 |
5.52 |
|
800 |
2.57 |
4.03 |
|
900 |
2.74 |
3.73 |
|
1000 |
2.92 |
3.50 |
|
1500 |
3.70 |
2.80 |
|
1800 |
4.12 |
2.50 |
|
2000 |
4.39 |
2.31 |
|
2200 |
4.63 |
2.19 |
|
2400 |
4.88 |
2.08 |
|
2500 |
5.01 |
2.02 |
|
3000 |
5.63 |
1.79 |
|